Understanding How Magnetic Flowmeters Work and the Difference between AC and DC Excitation


The electromagnetic flowmeter, commonly known as the "magmeter", gets its name from the magnetic field generated within the float tube that produces a signal proportional to flow. This principle employs Faraday's Law of Electromagnetic Induction. Magnetic flowmeters are built so the direction of the magnetic field is perpendicular to the flow and the line between the electrodes is also perpendicular to the flow. As a conductive liquid flows through the flowtube, an electro-motive force is generated. The electrodes detect the electro-motive force. The electro-motive force is proportional to the flow velocity, flux density, and the meter inner diameter. The flux density of the magnetic field and the meters inner diameter are constant values, therefore the magnetic flow meter can calculate the flow velocity and volumetric flow from the electro-motive force.

The basic components of the magnetic flow meter body are:

  1. A lined flowtube (typically Teflon)
  2. Excitation coils
  3. Two electrodes mounted opposite of each other within the flowtube.

Current is applied to the coils in the magmeter to generate a magnetic field within the flow tube. As a conductive fluid flows through the meter, an electro-motive force is generated. This force is detected by the electrodes and the resulting value is converted to flowrate.

For more information on magnetic flowmeters, contact Miller Energy, Inc. by calling 800-631-5454 or by visiting https://millerenergy.com.

6 Benefits of Using Wireless Networking Systems in Industrial Applications

Wireless Networking Systems in Industrial ApplicationsWireless technologies offer great value over wired solutions. A reduction in cost is just one of the many benefits of switching to the wireless networking system. There are many benefits, including enhanced management of legacy systems that were previously not possible with a wired networking connection.

Here is an overview of some of the value-added benefits of adopting wireless networking in industrial plants.
  1. Reduced Installation Costs - Savings in installation costs is the key benefit of a wireless networking system. The cost of installing a wireless solution is significantly lower as compared to its wired counterpart. Installing a wireless network requires less planning. Extensive surveys are not required to route the wires to control rooms. This reduced installation cost is the main reason industrial setups should consider going wireless instead of having a wired networking system. 
  2. Improved Information Accuracy - Adopting wireless networking also results in improved accuracy of information. The wireless system is not prone to interferences. As a result, the system ensures consistent and timely transfer of information from one node to another. 
  3. Enhanced Flexibility - Enhanced flexibility is another reason for deploying wireless networking solutions in an industrial setting. Additional points can be awarded easily in an incremental manner. The wireless system can also integrate with legacy systems without any issues. 
  4. Operational Efficiencies - Migrating to wireless networking can help in improving operational efficiencies as well. Plant managers can troubleshoot and diagnose issues more easily. The system facilitates predictive maintenance by allowing the monitoring of remote assets. 
  5. Human Safety - Another critical factor that should influence the decision to migrate to wireless networking is the human safety factor. Wireless technologies allow safer operations, reducing exposure to harmful environments. For instance, a wireless system can be used in taking a reading and adjusting valves without having to go to the problematic area to take measurements. With wireless networking systems, readings can be taken more frequently that can help in early detection and reduction of possible incidents. 
  6. Efficient Information Transfer - Another advantage is that the time required to reach a device is reduced. This results in a more efficient transfer of information between network segments that are geographically separated. The industry wireless networking standards use IP addresses to allow remote access to data from field devices. 

For more information on wireless technologies in industrial settings, contact Miller Energy by visiting https://millerenergy.com or by calling 800-631-5454.

Selecting the Right Magnetic Level Indicator

Companies in the process industry need the ability to visually monitor liquid levels in vessels (boilers, storage tanks, separators, etc.). Traditionally, armored glass sight gauges have been used. However, many companies want an alternative to sight gauges to avoid problems such as breakage, leaks, or bursting at high pressures and temperatures. In addition, the visibility of the sight glass can be poor and often affected by moisture, corrosion, or oxidation.

Many companies are increasing the use of automation and desire a 4–20 mA, HART®, FOUNDATION® fieldbus, or other output for level—which is difficult to do with a sight glass. Magnetic level indicators (MLIs) do not have the shortcomings of glass sight gauges and are suitable for a wide variety of applications.

Orion Instruments, a Magnetrol company, has authored an excellent Magnetic Level Indicator selection guide.


Miller Energy, Inc.
https://millerenergy.com
In NY/NJ 800-631-5454
In Eastern PA 888-631-5454

Understanding How Flame Arresters Work


Flame Arrester
A Flame Arrester (or arrestor) is a passive devices with no moving parts, that allows hot gas to pass through, but stops a flame in order to prevent a larger fire or explosion.  Flame Arresters uses a wound metal ribbon type element that prevents the spread of flame from the exposed side of the arrester to the protected side of the arrester. The metal element's construction provides a matrix of engineered openings that are carefully calculated and sized to quench the flame by absorbing the flame's heat. As an explosion flame travels through a narrow metal space, heat is transmitted to the walls, energy is lost and only vapor gasses are able to pass through. Flame Arresters are used in many industries chemical, petrochemical, pulp and paper, refining, pharmaceutical, mining, power generation, and wastewater treatment.

Cashco Flame Arresters are specifically engineered to match the explosive mixtures Maximum Experimental Safe Gap, in order to ensure complete extinction of the flame. At the heart of each Cashco flame arrestor lies filter discs that consists of wound, smooth and channeled strips of stainless steel set at specific maximum experimental stage gaps the smaller the gaps are which the flame travels the more heat and energy is lost therefore the filters gap width and gap length are specifically engineered to match the explosive mixture in order to ensure complete extinction of the flame. 

To learn more about Cashco flame arrestors, contact Miller Energy, Inc. by calling 908-755-6700 or by visiting https://millerenergy.com.


The Yokogawa 4-Wire SENCOM™ SMART Sensor Platform

Analyzer FLXA402
Multi-Channel/Parameter Analyzer FLXA402
The SENCOM SMART Sensor Platform has been designed with a strong focus on Yokogawa's digital SMART sensors and provides greater insight and enhanced capabilities for more reliable data across the entire product lifetime.

Yokogawa's latest SMART sensor system enhances the operation, reliability, and credibility of online process analyzers, from the engineering and purchasing to modification and optimization, by using the latest sensing technologies and asset management tools.

The SENCOM SMART Sensor Platform has been designed with a strong focus on Yokogawa's digital SMART sensors and provides greater insight and enhanced capabilities for more reliable data across the entire product lifetime.

Digital SMART SENCOM™ Adapter, SA11
Digital SMART SENCOM™ Adapter, SA11
Yokogawa's latest SMART sensor system enhances the operation, reliability, and credibility of online process analyzers, from the engineering and purchasing to modification and optimization, by using the latest sensing technologies and asset management tools.

Simple Setup and Configuration

Analog sensors equipped with a Variopin connector and Yokogawa ID chip
Analog sensors
The SENCOM 4.0 Platform is designed with an intuitive menu structure, easy-to-understand configuration, alarm settings, and clear error-fixing information to help you make credible and reliable measurements of online process control.

Environmentally Friendly Design

Conventional SMART sensors include integrated electronics on top of an analog sensor, therefore the still operating electronics must be thrown away once the sensor has reachable the end of its lifetime, adding to global waste.

The SENCOM 4.0 platform includes a reusable SMART adapter, so only an analog sensor has to be removed when it reaches the end of its lifetime, thereby reducing waste and costs.

Easy and Efficient Maintenance

Optional Digital SMART SENCOM™ Expansion Junction Box, BA11
Optional Digital SMART SENCOM™
Expansion Junction Box, BA11
The Maintenance Manager is a data management system that allows technicians to forecast maintenance and calibration frequency, estimate the service life of the sensor, and estimate the life expectancy of the sensor.

Calibration data are stored within the memory chip of the SMART sensor using the SENCOM 4.0platform. Once the sensor is connected to the analyzer, it is possible to download or upload the latest calibration data to the FLXA402 analyzer, thus avoiding the need for field calibration.

For more information, visit this page on the Miller Energy website.

Miller Energy, Inc.
800-631-5454

Level Instruments for Tank Overfill Protection

Tank overfill incidents in recent years have resulted in loss of life and billions of dollars in damages to petroleum facilities worldwide. One of the worst incidents - the overflow of a gasoline storage tank at Buncefield Oil Depot (U.K.) - has been traced to the failure of level control to maintain containment of the flammable liquid. More common are minor spills that cause significant environmental impact and result in millions of dollars in clean-up fees and environmental agency fines.

In the wake of this incident, the American Petroleum Institute’s (API) Recommended Practice (RP) 2350, the most widely accepted guideline for overfill protection of petroleum storage tanks, has been revised. The fourth edition was published in May 2012 and combined the prescriptive standards of RP 2350 with the functional safety standards of Safety Instrumented Systems (SIS) as described in IEC 61511.

Vital to these new requirements is the application of level instrumentation as one part of a comprehensive Overfill Prevention Process (OPP).

Magnetrol, a world-leader in the design, manufacturer and application of level and flow instrumentation, has written an application document titled "Level Instruments for Tank Overfill Protection". Get your copy here.