A blog specializing in pressure, temperature, level and flow instrumentation, control valves, process analyzers, and all other areas of process measurement. Courtesy of Miller Energy, a New Jersey, New York, Pennsylvania, and Ohio process instrumentation Rep and Distributor.
Setting Up the United Electric Controls Series One Safety Transmitter
Here is a two part tutorial showing how to setup your United Electric Series One Safety Transmitter. If you need any additional help or product information, reach out to a product specialist.
Safety Transmitters For Temperature and Pressure
Series One Safety Transmitter United Electric Controls |
The United Electric Controls (UE) Series One is a SIL-certified (Safety Integrity Level) transmitter designed solely for safety, alarm, and shutdown. With reliability, speed, and reduced nuisance trips an integral part of its design, the Series One is suitable for application in new installations, or easily integrated into existing operations.
A typical safety loop consists of sensors (such as a pressure or temperature transmitter), controllers, and final control elements. Most SIL-rated pressure transmitters require 300ms to communicate with the controller, then up to 500ms for the controller to send a signal to the final control element (such as a valve). This combined response time may insufficient for some applications. Incorporating the One Series Safety Transmitter, directly connected to the final control element, the total signal time is reduced to 100ms - a large and significant time savings when safe operating conditions have been breached. When used with blowers, pumps and compressors, the One Series makes up a complete safety system with a self-contained sensor, controller, and final control element (the switch) capable of SIL2 without additional safety instrumented function (SIF) components.
The below document provides detailed information about the Series One. Share your process safety challenges with the instrumentation specialists and combine your process knowledge with their product application expertise to produce effective solutions.
Opportunity For Improving Power Plant Heat Rate
Opportunities for improving efficiency at power plants |
One area of the steam cycle that may be a candidate for improvement is the feedwater heater. This device is essentially a shell and tube heat exchanger used to recover waste heat from the process and use it to preheat boiler feedwater. Maintaining the correct liquid level in the feedwater heater is a key element of extracting maximum performance. Magnetrol, a globally recognized leader in the development of level measurement equipment, has produced a video showing how their technology can be used in an advantageous manner to others in regulating feedwater heater liquid level and achieving maximum efficiency.
Handbook on pH and ORP Measurement
Dual input pH analyzer and transmitter Courtesy Yokogawa |
The book provided below, authored and provided by Yokogawa Electric Corporation, provides a comprehensive understanding of pH/ORP measurement and how to achieve reliable results. Basic information on the principles of measuring pH/ORP, construction of the sensing elements, and their basic use in process applications is provided.
A part of achieving accurate and reliable pH/ORP measurements includes the provision of sufficient electrode strorage conditions and proper maintenance. Prevention of common errors during maintenance and storage, as well as consistent detection of loop failures is important. This book describes how to avoid pitfalls and detect failures.
The book is accompanied with a frequently asked question and answer section as well as an appendix that includes helpful information like a Chemical Compatibility Table and a Liquid-Application-Data-Sheet, which can be used to describe the user’s application.
Miller Energy Introductory Video
Miller Energy is a Manufacturer's Representative and Distributor of Industrial Instrumentation and Process Control Equipment. Since 1958, Miller been committed to exceeding our customers expectations by providing an unparalleled level of customer service and local technical support.
Miller Energy maintains two office locations in NJ and PA. The South Plainfield, NJ operation services the areas of Northern NJ, New York, and Fairfield County Connecticut and serves as our corporate headquarters. The Exton PA office serves the areas of Southern NJ, Eastern PA, Delaware and Maryland.
Safety Transmitters Achieve Safety Goals With Reduced Cost and Complexity
Series One Safety Transmitter United Electric Controls |
In sensor subsystems, United Electric’s certified safety transmitter for pressure or temperature provides a less costly, simple path for process designers, instrument and control engineers, and maintenance personnel. The Series One Safety Transmitters combine several useful safety and monitoring functions into a single, easy to deploy device. Products are available for gauge pressure, differential pressure, and temperature applications. In addition to a 4-20 mA process variable output, the Series One has an embedded programmable high-capacity relay certified as a safety variable output. The Series One Safety Transmitter provides designers the option of a hard wired trip in less than 100 milliseconds, with a tenth of a percent repeatability, along with the monitoring functions of a traditional continuous analog output.
For equipment under control requiring protection, or processes where rapid excursions can initiate dangerous events, this unique pressure and temperature transmitter is addressing process safety time constraints, coupling issues with PLC and DCS units, and adding diversity to the safety instrumented function.
There is a whole lot more to learn about these "Safety right out of the box" industrial pressure and temperature safety transmitters. A product data sheet is provided below, but you can get the latest and most detailed product and application information from a specialist in industrial process measurement and control. Share your safety instrumentation challenges with them, combining your process expertise with their product application knowledge to develop effective solutions.
Yokogawa Data Acquisition Unit Product Changes
The DX1000 and DX2000 are among the potential replacements for the discontinued CX Series |
The model CX 2000 was discontinued at the end of February. It combined data acquisition, display, control, and networking in a single unit. A scaled down version, CX 1000 was previously discontinued. The company recommends possible replacements to include one or more of the following products:
- Advanced Application Temperature Controller UT75A
- Button Operated DX1000/DX2000
- General Purpose Temperature Controller UT35A/UT32A
- Mid-level Temperature Controller UT55A/UT52A
- TC10 Temperature Controller
- Touch Screen GX10/GX20
- US1000 Digital Indicating Controller
- UTAdvanced UT32A-D
- UTAdvanced UT32A-V/C/R
The DX2000 Daqstation is a mature product with a solid portfolio of field installations. It can accommodate display, recording, networking, and storage of data on up to 48 input channels. Input types include DC voltage, contact signal, RTD, and thermocouple. Ethernet connection enables remote access via a website and the unit can provide email alerts. There are numerous effective and user-friendly features included with the DX2000, which incorporates Yokogawa's decades of experience with recording and data acquisition.
Whatever your data acquisition needs and challenges, the best solutions will result from combing your process expertise with the knowledge of a product specialist. Reach out to them and get results.
Subscribe to: