An Excellent Replacement for the Discontinued Siemens 353 SLC

Siemens 353 replacement
The Yokogawa YS1700 is a great replacement to the
discontinued Siemens 353 SLC controller.

The discontinuation of the Siemens 353 SLC controller is a concern to many users of this popular controller. With few alternatives, customers are joking that they'll have to turn to eBay for spare parts. There's a much better solution though. The Yokogawa YS1700 PID loop controller, a drop-in replacement for the Siemens 353 SLC.

The Yokogawa YS1000 Series is the ideal choice for many control applications offering extreme reliability and sophisticated control. This product family has bright, easy-to-read displays, multiple I/O points, and powerful loop tuning. For critical applications, the YS1700 employs dual CPUs for maximum reliability and hard-manual control for added protection. The YS1700’s powerful function block programming allows for custom strategies to control many demanding processes such as boilers and steam generators, PH control, dosing control, and many other demanding plant processes.

To learn more about replacing the Siemens 353 with a Yokogawa YS1700, visit this page or go directly to this link https://millerenergy.com/Siemens-353-Replacement.

How to Select a Pressure Switch

UEC One Series Switch Transmitter Hybrid
UEC One Series Switch Transmitter Hybrid
Reprinted with permission from United Electric Controls

Pressure switches are widely used by many industries and within many applications. The basic function of a pressure switch is to detect a pressure change and convert it into an electrical signal function – typically on/off or off/on. Pressure switches may be of electro-mechanical or electronic/solid-state design (see our ONE Series); and while each may have its advantages, arriving at the correct pressure switch for your application is the same.

Set Point & Deadband


Application set point (sp) is the desired value reached at rising or falling pressure at which the micro-switch changes electrical states. Depending upon the pressure switch function, the micro-switch could be wired to open (turn something OFF)  or close (turn something ON) when set point is achieved, thereby triggering an event such as an alarm, equipment shutdown, or powering up secondary equipment. Ideally, the set point should fall into the mid 50% of the pressure switch range for best performance including repeatability and long life. On an electro-mechanical pressure switch, set point may be adjusted internally or externally either through blind adjustment or reference dial. An electronic pressure switch would have internal or external adjustment via a key pad and digital display or a handheld programmer.
Deadband graph

Deadband (DB) is the on-off differential required to reset the micro-switch. This value may be fixed or adjustable with an electro-mechanical switch and may be up to 100% adjustable on an electronic switch.

Deadband may be an important factor to consider depending upon the application requirements.

System Pressure


Knowing your normal and maximum system pressures will help in selecting a pressure switch with appropriate minimum and maximum operating parameters. Once your set point is established, other factors to consider are vacuum and/or surge pressure that could affect switch operation. This would involve maximum working pressure, over range pressure, and proof pressure specifications of a pressure switch. The relationship between set point and system pressure has a direct effect on switch performance and life.

Electrical Considerations


UEC 100 Series Pressure Switch
UEC 100 Series Pressure Switch
Micro-switches are available in a variety of configurations. The most common for electro-mechanical pressure switches is 15A, 480VAC SPDT (single pole, double throw). The advantage of a SPDT micro-switch is that it offers wiring flexibility to either open or close on pressure change. Other micro-switches available include 1A with gold contacts, useful when working with a PLC, or at the upper end, 30A when switching certain high voltage heaters or motors. Adjustable micro-switches help with deadband adjustment. A DPDT (double pole, double throw) micro-switch would provide two simultaneous functions off of one micro-switch. If a low-high limit alarm and shutdown were required, there are pressure switches that include two SPDT micro-switches that are independently settable.

An electronic pressure switch would use solid-state relays to change states. Like an electro-mechanical switch, the electronic switch can be programmed to open or close on rising or falling pressure. There are different capacities for switching voltage and current depending upon the application requirements.

Process Media and Wetted Parts


The pressure connection and sensor are known as wetted parts since they come into direct contact with the process media. Sensor material is either elastomer (i.e. Buna-N, Teflon®) or metallic (i.e. Brass, Stainless Steel) with metallic or composite pressure connections. The process media must be compatible with the wetted parts material. Process media temperature should also be considered as each of the different wetted materials would have differing operating properties.

Pressure Switch Mounting


If the unit is to be installed directly onto the process, there are many methods of installation.
Typically a 1/8”, 1/4”, or 1/2” NPT (national pipe thread taper) connection is used with a mating
fitting to secure the pressure switch to the process. There are also straight threaded (SAE, BSPT)
connections, flush mount connections, and sanitary connections. The pressure switch may be
mounted directly in the process line using the threaded connection, a manifold, or flange; or the
enclosure could be bolted to a mounting plate or other plane to secure it. If heavy vibration is
present, you may choose to use a remote diaphragm seal with the pressure switch. The diaphragm
seal mates with the process connection while the pressure switch enclosure is mounted securely
away from the vibration. 

Process Environment


It is important to know what type of environment the pressure switch would be installed in – hazardous or ordinary location; indoors or outdoors; exposed to salt air; inside a control panel; in high ambient temperature. These are just some of the factors to consider so the right enclosure type is chosen. Enclosure types come in many shapes, sizes, and materials. They also conform to various industry and third-party approval standards. Electronic switches can be used to replace electro-mechanical switches when SIL is needed for safety applications.  There are also electro-mechanical pressure switches without enclosures; typically used in OEM, non-hazardous locations where the environment is benign.

With careful consideration of all the factors listed above, choosing a pressure switch is a snap. If you are at all unsure, please contact your local United Electric Distributor or visit the UE Product Selector to find your pressure switch.

Miller Energy, Inc. - Expertly Serving These Industries in the Mid-Atlantic Region

Miller Energy is a Manufacturer's Representative and Distributor of Industrial Instrumentation and Process Control Equipment with offices in South Plainfield, NJ and Exton, PA. In business since Since 1958, Miller's success is attributable to their commitment to exceeding their customers expectations and a comprehensive line of "best-of-breed" measurement, control, and communication products. With a strong reputation for unparalleled customer service and expert local technical support,  Miller Energy continues to demonstrate strong growth in the Mid-Atlantic region.


https://millerenergy.com
908-755-6700 NJ
610-363-6200 PA

Radiometric, Non-contact Level Measurement for Liquids or Solids

Radiometric level detection
Radiometric level detection
(RONAN)
Radiometric level measurement, using a very low gamma level source, is designed to deliver outstanding performance in a wide range of difficult applications and process conditions for both liquids and bulk solids which include the most dangerous materials such as caustic, toxic, corrosive, explosive, and carcinogenic irrespective of their viscosity and temperature.

These level gauges meet “As-Low-As-Reasonably-Achievable” (ALARA) guidelines. Source activity is customized depending on vessel and process parameters such as diameter, wall thickness, material, and measurement span to ensure optimum sensitivity, economy and safety while keeping the source activity to a minimum.

Non-contact level
Sources and Detector Mounted
External to Vessel
An exclusive “Radiation Low Level” (RLL) source holder uses up to 100 times less gamma energy than comparable gauges, and is the only source holder recognized by the NRC to be so safe that it does not require the stringent documentation, training or handling procedures of other systems.

Operation

Radiometric level measurement provides a safe and efficient, non-contact method to measure liquids or solids in harsh process environments. Each system consists of a gamma source, detector and microprocessor.

  • The gamma source, typically mounted external to the vessel emits energy through the vessel walls collimated in a direction towards the detector mounted on the opposite side of the vessel. The gamma energy reaches the detector when the vessel is empty. As the process level rises in the vessel, the gamma energy reaching the detector will decrease in an inversely proportional relationship to the level. 
  • The detector measures the level of energy and sends a proportional signal to the microprocessor. 
  • The microprocessor linearizes, filters, and correlates this signal to a level measurement. 

The entire system is mounted external to the vessel and can be easily installed and maintained while the process is running ... without expensive down time, vessel modifications or chance of accidental release.

Applications
Low Level Source and Detector
Low Level Source and Detector
Mounted External to Vessel
  • Radiometric level detection
  • Low Level Source and Detector
  • Mounted External to Vessel
  • Solids or Liquid Measurement 
  • Measurement Not Affected by: 
  • Internal Obstructions. i.e. Agitators Extreme Process Temperatures 
  • Caustic Processes 
  • Violent Product Flow 
  • Sterile Process 
  • Changing Process 
  • Variable Product Flow 
  • Automatic Compensation for Vapor Density Changes 
  • Automatic Compensation for Foam or Gasses 
  • Automatic Compensation for Process Build-Up 
  • Detectors Contoured to the Shape of Vessels 
  • Upgrade Utilizing Existing Sources
Features and Benefits 
  • Accurately Measures the Most Complex Processes 
  • Solid Crystal or Flexible Scintillating Fill- Fluid 
  • Excellent Measurement Reliability due to Proprietary Filtering Technology 
  • Level Detection of Multiple Interfaces 
  • Low Maintenance / No Component Wear 
  • Auto-Calibration

For more information in Eastern Pennsylvania, New Jersey, Metro New York or Delaware contact:
Miller Energy by visiting https://millerenergy.com or by calling 908-755-6700 in New Jersey, or 610-363-6200 in Pennsylvania.

Yokogawa Users Conference 2018

The 2018 Yokogawa Users Conference and Exhibition – North America brings together hundreds of industry experts and valued users to exchange knowledge, share best practices and innovative solutions to real-life day-to-day challenges.
  • Sept. 10-13, 2018
  • Renaissance Orlando at Seaworld, Florida

Attendees experience unique and exciting opportunities to learn more about Yokogawa's solutions and how they can be applied to achieve safe, reliable, and profitable operations.
  • Network: Develop a knowledge-sharing session within a diverse network of users and mingle with industry peers
  • Discover: Gain insights into the latest industry practices and trends from the visionary leaders across prestigious major international and national companies
  • Innovate: Learn more about new products, innovations, and user experiences on how they maximize profit potential and improve their plant process while dealing with complex problems

Happy 4th of July from Miller Energy!


“America is another name for opportunity. Our whole history appears like a last effort of divine providence on behalf of the human race.”

Ralph Waldo Emerson

Industrial Refractometers Used in Process Control

Refractometer Pharmaceutical Use
Refractometer for pharmaceutical use (K-Patents).
Part physics, part material science and part chemistry, refractometry is the process which measures the composition of known substances by means of calculating their respective refractive indexes (RI). RIs are evaluated via a refractometer, a device which measures the curve, or refraction, resulting when the wavelength of light moves from the air into and through a tested substance. The unitless number given by the refractometer, usually between 1.3000 and 1.7000, is the RI. The composition of substances is then determined when the RI is compared to a standard curve specific to the material of the substance.

Process refractometers provide the analysis to quickly, reliably, and very accurately identify a sample and determine it's concentration and purity levels. They measure the refractive index and temperature of flowing liquids, and apply mathematical functions to determine the concentration of dissolved solids.

Common industrial refractometer applications are:
  • Calculating beverages’ amount of sugar dissolved is water.
  • In commercial food applications such as juice production or tomato processing, refractometers are used to measure degrees Brix (Tthe Brix scale relates refractive index to sugar concentration, and is a key way to maintain consistency).
  • In the pharmaceutical industry, process refractometers are used to monitor and control concentration levels during supersaturation, a critical process in crystallization.
  • In pulp and paper production, process refractometers for measuring dissolved solids in black and green liquor during the chemical recovery process.
Equipment manufacturers have developed numerous refractometer configurations tailored to specific each use and application. Each has a set of features making it the advantageous choice for its intended application. Product specialists can be invaluable sources of information and assistance to potential refractometer users seeking to match the best equipment to their application or process.

For more information on industrial refractometers, contact Miller Energy by visiting https://millerenergy.com or by calling 908-755-6700 in New Jersey or 610-363-6200 in Pennsylvania.