White Paper: Using Digital MFC Capabilities to Improve Bioprocessing Results Miller Energy

Biomanufacturing relies on numerous pieces of equipment working in concert to produce life-altering therapeutics. The equipment relies on various subsystems to achieve the desired results. In a bioreactor, one of the most essential subsystems provides gas management for the gases necessary for cellular metabolism. At the heart of the gas management subsystem is the thermal mass flow controller (MFC), a component that precisely measures and controls the delivery of gases to the bioprocess.

This white paper, courtesy of Brooks Instrument, discusses mass flow controller data capabilities in relation to a broader biomanufacturing capital asset management.


For more information on Brooks Instrument products, contact Miller Energy. Call them at 800-631-5454 or visit their website at https://millerenergy.com.

Programming the UE One Series Hybrid Transmitter-Switches


The United Electric Controls One Series electronic pressure and temperature transmitter-switches are designed to provide transmitter, switch and gauge functions all-in-one rugged enclosure that can withstand the rigors of harsh and hazardous environments. Available in Type 4X enclosures approved for intrinsic safety, flameproof and non-incendive area classifications, these hybrid transmitter-switches have a fully adjustable set point and deadband and 0.1% repeatability. This video provides a quick tutorial on how to set up the One Series.

For more information, contact Miller Energy. Call them at 800-631-5454 or visit their web site at https://millerenergy.com.

Happy Holidays from Miller Energy


A time of peace, a season of wonder and joy... We wish you all the best during the holidays and through the coming year, from all of us at Miller Energy.

Don’t Let Valves Come Between You and Accurate Flow Measurement

Getting valves and flow meters to work together is sometimes a challenging task within industrial water and wastewater applications. Valves tend to create the kind of irregular media flow patterns in pipelines that make it a real challenge to achieve accurate flow measurement of liquids, gas or steam. That’s why many types of popular liquid flow meters require straight pipe runs.

Unfortunately, the nature of the process or the kind of space required for long straight runs of pipe is often an impossible luxury in many of today’s plants.



How Valves Create Flow Disturbances


Depending on a pipeline’s flowing media (liquid, gas or steam), the process pressures and the process temperatures, the fluid flow dynamics within a pipeline can vary widely. The ideal pipeline configuration for the accurate measurement of flow with nearly all of the industry’s most popular flow sensors is a straight pipe with consistent media conditions Many processes by their very nature, however, tend to be unstable and create irregular flows within a pipeline all by themselves.

Plant layouts, especially expansions and retrofits, also tend to create less than optimum pipeline conditions for the measurement of flow. The addition of valves, pumps, elbows and other equipment into the pipeline create media swirling and other effects that can result in irregular flow profiles that will reduce flow meter measurement accuracy and repeatability. That’s why many flow meter manufacturers recommend anywhere from 5 to 10 or even 20 to 30 pipe diameters of straight pipe run upstream and downstream of the flow meter—depending on the flow sensing technology in use.

Flow Straightening and Conditioning


While the simple solution is to know your flow meter and its straight pipe run requirements to achieve accurate, consistent measurement, this is often easier said than done. Today’s complex and ever changing industrial processes, the need to treat and conserve water, crowded plant environments where real estate is precious, regulatory requirements and the team involved in running any plant can mean that your valve or elbow inevitably intrudes on your flow meter’s turf. Many times the first sign of the problem is when the flow meter isn’t reading the flow accurately. By then changing the pipeline layout or moving other devices such as valves is impractical and too costly.

Flow straighteners and conditioners offer an answer to this problem. There are several different types of flow straighteners and conditioners, including perforated plates, tube bundles, etc. The purpose of all flow straighteners and conditioners is to eliminate swirl and provide a stable velocity flow profile. Of course the ideal time to think about flow conditioning is before the flow meter is installed so that the flow conditioner and flow meter can be calibrated to work together. One drawback to add-on flow conditioners and straighteners is that they increase head loss.

Flow Meters With Built-In Conditioning


Another solution to consider is the installation of a flow meter with built-in flow conditioning. This type of solution offers the advantages of installation flexibility, reduced equipment, simplified installation with potentially fewer pipe penetrations and reduced maintenance requirements. Several manufacturers offer flow meters that include built-in flow conditioning. For example, McCrometer’s V-Cone Flow Meter is a differential-pressure sensing meter with integral flow conditioning that operates within liquids, gas or steam.

McCrometer’s V-Cone Flow Meter
McCrometer’s V-Cone Flow Meter
The V-Cone’s DP flow sensor conditions fluid flow to provide a stable flow profile that increases accuracy. The flow sensor‘s design features a centrally-located cone inside a tube. The cone interacts with the fluid flow and reshapes the velocity profile to create a lower pressure region immediately downstream. The pressure difference, which is exhibited between the static line pressure and the low pressure created downstream of the cone, can be measured via two pressure sensing taps. One tap is placed slightly upstream of the cone and the other is located in the downstream face of the cone itself. The pressure difference can then be incorporated into a derivation of the Bernoulli equation to determine the fluid flow rate.

The cone’s central position in the line optimizes the velocity of the liquid flow at the point of measurement. It forms very short vortices as the flow passes the cone. These short vortices create a low amplitude, high frequency signal for excellent signal stability. The result is a highly stable flow profile for measurement accuracy to +0.5% with +0.1% repeatability over a wide flow range of 10:1. All of this is possible with a minimal straight pipe run of 0 to 3 diameters upstream and 0 to 1 diameters downstream from the flow meter depending upon placement from valves and other control devices.

Conclusions


Getting accurate flow measurement with valves, pumps, and other equipment in relatively close proximity is difficult, but achievable. The ideal way to achieve accurate and repeatable flow measurement within industrial water and wastewater applications is to recognize in advance the straight pipe run requirements of the flow sensing technology in use at your plant. When the process, the plant layout or other factors lead to swirl in your pipeline that affects meter performance, then consider either flow conditioners or a flow meter with built-in flow conditioning.

Attribution: Original white paper written by Jim Panek, Product Manager, Water & Wastewater, McCrometer, Inc.

Tutorial: The Yokogawa SMARTDAC+ GX/GP Paperless Recorder Channel Settings


The Yokogawa SMARTDAC+ GX and GP are fully integrated measurement, display, and recording platforms equipped with an advanced touch screen operator interface. GX series is a panel-mount design, capable of operating in harsh industrial applications and environments. GP is the portable version of the GX, intended for use in lab and test bench applications.

This video is a tutorial to learn the display settings available within the SmartDAC+  GX/GP's analog input, digital input, digital output, math, and communication channel settings.

For more information about the Yokogawa SMARTDAC+ GX/GP Paperless Recorder contact Miller Energy, Inc. Call them at 800-631-5454 or visit their web site at https://millerenergy.com.

Celebrating Those in the Armed Forces Who Serve and Protect This Country

Veterans Day

Veterans Day is set aside to honor the men and women who have sacrificed so much in order to serve in the armed forces of the United States.

Veterans Day celebrates and thanks all United States military veterans,  alive or dead, and honors the sacrifices that they have made. Our Veterans are our neighbors, friends, family, and co-workers. They took an oath to defend the United States and our Constitution, from all enemies, foreign and domestic. We must never forget their bravery, service, and sacrifice.

Originally called Armistice Day because of the November 11 Armistice that ended World War I, its name was officially changed in the United States in 1954 to Veterans Day to include Veterans of all wars.

Through the observance of Veterans Day, we remind ourselves of our Veterans patriotism, love of country and willingness to serve and sacrifice for the common good.

Miller Energy celebrates and honors America's veterans.